HCL-B1 Hydrogen Chloride Sensor

HCl Gas Sensor, Electrochemical, B-Series, 0–100 ppm range

Hydrogen chloride gas sensor for fixed and high-humidity industrial applications

The HCL-B1 is a 0–100 ppm hydrogen chloride sensor in the B-Series format, optimised for fixed gas detection in semiconductor fabs, stack emissions, process control and high-humidity industrial environments. With 120–250 nA / ppm sensitivity at 25 ppm HCl and T90 < 200 s, it combines strong signal output with robust stability. Cross-sensitivities are well characterised, and the sensor carries a 12-month warranty; operating life depends on application conditions.


  Request Quote   Buy Online   View Datasheet

Key Specifications:

 

2

Sensor Model

Target Gas

Package Size

Concentration Range

Sensitivity

T90 Response Time

Lifetime / Warranty

HCL-B1

Hydrogen Chloride (HCl)

B-Series

0–100 ppm HCl

120 to 250 nA / ppm ( in 25 ppm HCl)

< 200 s (0 →25 ppm step)

12-month warranted (operating life application-dependent)

 

Feature

Benefit

B-Series package for fixed systems

Supports long-term, high-humidity operation in ducts and process lines.

High sensitivity (120–250 nA / ppm)

Provides strong signal for low-noise 4–20 mA or digital transmitters.

Defined cross-sensitivity profile

Enables predictable performance around other combustion and process gases.

Temperature-characterised zero and sensitivity

Facilitates accurate temperature compensation over −30 to +50 °C.

Compatible with IST “+” options

On-board memory and temperature sensing support plug-and-play replacement.