H2-AF Hydrogen Sensor
H2 Gas Sensor, Electrochemical, A-Series, 0–2,000 ppm filtered
Filtered hydrogen sensor for portable and fixed safety monitoring
The H2-AF is a 0–2,000 ppm hydrogen sensor in the A-Series package, designed for portable and fixed instruments used in battery rooms, confined spaces and industrial safety. With 10–40 nA / ppm sensitivity at 400 ppm H2 and T90 < 35 s, it delivers a strong, repeatable response combined with low CO cross-sensitivity. A filter capacity rated in H2S ppm-hours, together with > 24-month operating life, provides robust performance in mixed-gas environments.
| Request Quote | Buy Online | View Datasheet |
Key Specifications:
|
Sensor Model |
Target Gas |
Package Size |
Concentration Range |
Sensitivity |
T90 Response Time |
Lifetime / Warranty |
|
H2-AF |
Hydrogen (H2) |
A-Series |
0–2,000 ppm H2 |
10 to 40 nA / ppm (in 400 ppm H2) |
< 35 s (0 →400 ppm step) |
> 24 months (24-month warranted) |
|
Feature |
Benefit |
|
0–2,000 ppm H2 range |
Covers leak detection and safety thresholds in battery rooms and process equipment. |
|
Low cross-sensitivity to CO |
Improves selectivity for H2 in combustion and industrial environments |
|
Fast T90 < 35 s |
Supports rapid alarm response for worker safety and asset protection |
|
Temperature-dependent behaviour characterised |
Repeatable temperature response enables accurate software compensation |
|
Filter capacity for H2S |
Protects the sensor in environments where hydrogen sulphide may be present |
-
Technical Datasheet
Application Notes
- Health and Safety Information
- Design notes on hydrogen sensor temperature compensation and cross-sensitivity.
Design Considerations
- Guidance on bias, load resistor selection and AFE design for H2 sensors.
Safety Documents
Related Products
- Accessories
- 4-20 mA Digital Board
- Foam Seal
- Dust Filter
- Gas Hoods
- Frequently bought together
- CO, O2 and LEL channels for multi-gas battery-room and utility monitors.
- Other related H2S sensors in the Alphasense portfolio:
- H2-BF B-Series sensor for extended-range fixed installations.