Specifications - Infrared Carbon Dioxide Sensors

  IRC-A1 IRC-AT
Maximum Power Requirement 5.0 VDC, 60mA max. (50% duty cycle source drive)  
Minimum Operating Voltage 2.0 VDC (50% duty cycle source drive)  
Source Drive Frequency 1.5 to 3 Hz (recommended 2 to 2.25 Hz)  
Active Output in N2 (peak-to-peak) 60 - 100mV @ 2.1 Hz, 50% duty cycle  
Reference Output in N2 (peak-to-peak) 40 - 80mV @ 2.1 Hz, 50% duty cycle  
Response Time (t90) < 40s @ 20°C ambient  
Warm-up Time To final zero ± 100ppm: < 30 s @ 20°C  
To specification < 30 minutes @ 20°C  
Operating Temperature Range -20°C to +50°C (linear compensation from -10°C to 40°C)  
Storage Temperature Range -40°C to +75°C (-40°F to 167°F)  
Humidity Range 0 to 95% rh, non-condensing  
MTBF > 5 years  
Temperature Signal
Integral thermistor (NTC, R25 = 3000 ohm, B = 3450 K)*
 

Measurement range

IAQ
Range 0 to 5000 ppm
FS Resolution 15 ppm
Accuracy (%FS, using universal linearisation coefficients) 1
Zero Repeatability ± 10 ppm
FS Repeatability ± 50 ppm

Safety
Range 0 to 5 % vol
FS Resolution 100 ppm
Accuracy (%FS, using universal linearisation coefficients) 1.5
Zero Repeatability ± 10 ppm
FS Repeatability ± 500 ppm

Combustion
Range 0 to 20 % vol
FS Resolution 500 ppm
Accuracy (%FS, using universal linearisation coefficients) 2.5
Zero Repeatability ± 10ppm
FS Repeatability ± 2500 ppm

Process control
Range 0-100 % vol
FS Resolution 0.5 % vol
Accuracy (%FS, using universal linearisation coefficients) 4
Zero Repeatability ± 10ppm
FS Repeatability ± 5000

 


Note: all sensors tested and stored at ambient environments unless otherwise stated. As applications of use are outside our control, the information provided is given without legal responsibility. Customers should test under their own conditions, to ensure that the sensors are suitable for their own requirements.

Please use PCB sockets when connecting Alphasense sensors. Soldering, gluing or other methods of connection will void your warranty.