Alphasense Chlorine gas
sensors operate using proven fuel cell technology.
Sensors are available in the following sizes:
A: 20mm diameter, the industry standard size for portable
gas detectors
B: 32mm diameter package, the best choice for fixed site
applications
D: miniature, with proven long-term performance,
for the next generation of gas detectors
The CL2 range provides OEMs with reliable sensors
for use in a number of high volume applications. Strong signal levels
combined with low zero current allows resolution to 50ppb and an
operating range of 20ppm. The sensors are suitable for inclusion
in fixed installation sensing heads and portable safety instruments.
These sensors show better transient response
to humidity changes, compared to competitors'
equivalent sensors.
The CL2 sensors offer
our electrolyte leak-free guarantee and reliable long-term detection
performance. The leakproof housing is moulded with a colour coded
top for ease of identification.
Alphasense tests the
performance of every sensor; results are stored on our database,
giving full traceability for all sensors. The unique Automatic Test
and Validation (ATAV) system controls initial sensor stabilisation
and runs complex tests under computer control. This computerised
system also ensures traceability as tested sensors are moved direct
to despatch with their unique barcodes. The ATAV system also runs
full validation testing, monitors sensors for long term performance
and its generated statistics are used for process control.
|