Alphasense Chlorine gas
sensors operate using proven fuel cell technology.
Sensors are available in the following sizes:
A: 20mm diameter, the industry standard size for portable
gas detectors
B: 32mm diameter package, the best choice for fixed site
applications
D: miniature, with proven long-term performance,
for the next generation of gas detectors
The Cl2 range provides OEMs with reliable
sensors for use in a number of high volume applications. Strong
signal levels combined with low zero current allows resolution to
20ppb and an operating range from +0 to 20ppm. The sensors are suitable
for inclusion in fixed installation sensing heads and portable safety
instruments.
These sensors have improved transient response
to humidity changes compared to competitors'
equivalent sensors.
The Cl2 sensors
offer our electrolyte leak-free guarantee and reliable long-term
detection performance. The leakproof housing is moulded with a colour
coded top for ease of identification.
Alphasense tests the
performance of every sensor; results are stored on our database,
giving full traceability for all sensors. The unique Automatic Test
and Validation (ATAV) system controls initial sensor stabilisation
and runs complex tests under computer control. This computerised
system also ensures traceability as tested sensors are moved direct
to despatch with their unique barcodes. The ATAV system also runs
full validation testing, monitors sensors for long term performance
and its generated statistics are used for process control.
|